3 digital input behavior define, 1 status per channel – Vivotek SD9161-H-v2 2MP PTZ Network Dome Camera User Manual
Page 195

VIVOTEK
User's Manual - 195
©
2022 VIVOTEK INC. All Right Reserved
44
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
di_i<0~(k-1)>
<product dependent>
<boolean>
1/7
0 => Inactive, normal
1 => Active, triggered
(capability_ndi > 0)
k is determined by the below
criterion:
The following applies for
capability_extension_di_num >= 0
* if extension_connected=1,
k=capability_ndi
* if extension_connected=0,
k=capability_ndi+
capability_extension_di_num
Otherwise,
* k=capability_ndi
do_i<0~(k-1)>
<product dependent>
<boolean>
1/7
0 => Inactive, normal
1 => Active, triggered
(capability_ndo > 0)
k is determined by the below
criterion:
The following applies for
capability_extension_do_num >=
0
* if extension_connected=1,
k=capability_ndo
* if extension_connected=0,
k=capability_ndo+
capability_extension_do_num
Otherwise,
* k=capability_ndo
onlinenum_rtsp
0,<positive
integer>
6/7
Current number of RTSP
connections.
onlinenum_httppush
0,<positive
integer>
6/7
Current number of HTTP push server
connections.
onlinenum_sip
0,<positive
6/7
Current number of SIP connections.
©
2022 VIVOTEK INC. All Right Reserved
45
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
integer>
eth_i0
<string>
1/7
Get network information from
mii-tool.
vi_i<0~(capability_nvi-1)>
<product dependent>
<boolean>
1/7
Virtual input
0 => Inactive
1 => Active
(capability_nvi > 0)
7.2.1
Status per Channel
Group:
status_c<0~(n-1)>
for n channel products
n denotes the value of "capability_nvideoin"
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
signal_detect
<boolean>
1/7
Indicates whether the video source is
connected or not.
* Only available when
capability_videoin_type is 0 or 1.
signal_type
ntsc,pal
1/7
The actual modulation type.
* Only available when
capability_videoin_type is 0 or 1.
daynight
day, night
1/7
Indicate the current light status.
7.3
Digital Input Behavior Define
Group:
di_i<0~(k-1)>
for k is the value of "capability_ndi"
(capability_ndi > 0)
k is determined by the below criterion:
The following applies for capability_extension_di_num >= 0
* if extension_connected=1, k=capability_ndi
* if extension_connected=0, k=capability_ndi+ capability_extension_di_num
Otherwise,
* k=capability_ndi
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
normalstate
high,
low
1/1
Indicates open circuit or closed circuit
(inactive status)