Section 3. Commands


109

Read Arguments

The optional argument x used in the

read

command specifies the type of data to read and y

specifies the text to be displayed. The following table describes the recognized x arguments for
the

read

command:

Read

Argument

Description

any

Read any type of data.
This option is equivalent to

read

without any arguments.

card

Read magnetic stripe card. Display message (

msg 1

) if defined.

When the user swipes a card, the response will be in the following format:

/read M

X

1

X

2

X

3

SS data

X

I

define the track read status for each of the three tracks, as follows:

0 = good track
1 = bad track
9 = no track data.

SS is a two-digit status code; it is not affected by errors reported in the

X

i

field:

00 – successful read
82 – canceled, etc.

data is the card data for all successfully read tracks.

card_w_pin

Read magnetic stripe card and collect PIN from cardholder. Display
messages if defined.
This command is similar to the

read

card

command except that after the

card is swiped, the device collects and stores the cardholder’s PIN. The
PIN can be collected later by issuing the

read pin

command.

Before issuing this command, the following properties may be set:

msg1

,

msg2

,

msg3

– messages to be displayed while waiting for card

swipe and PIN entry (a default message will be used if these properties
contain empty strings).

The response to this command is identical to the

read card

response; if

successful, it returns the track data from the magnetic card. If the response
status SS is 00, the

read pin

command can be used to collect the PIN.

check

Read check data.
When the user reads a check, the response will be in the following format:

/read C

X

1

X

2

X

3

SS data

XXX is the decimal representation of the check read status, as defined in

the MICR specification, e.g.,

004

indicates a bad character in the

check number field.

SS is a two-digit status code: 00 – successful read, 82 – canceled, etc.

This status is not affected by errors reported in the XXX

field.

data is the check data, which is also available in

chk_data

. The data

format depends on the setting of the

chk_format

property.