Result code, Get and set property commands – Elo TouchSystems 1525L User Manual

Page 76

Advertising
background image

Section 4. USB Communications


73

RESULT CODE

This one byte field contains the value of the result code. There are two types of result codes:
generic result codes and command specific result codes. Generic result codes always have the
most significant bit set to zero. Generic result codes have the same meaning for all commands
and can be used by any command. Command specific result codes always have the most
significant bit set to one. Command specific result codes are defined by the command that uses
them. The same code can have different meanings for different commands. Command specific
result codes are defined in the documentation for the command that uses them. Generic result
codes are defined in the following table.

Value Result

Code

Description

0

SUCCESS

The command completed successfully.

1

FAILURE

The command failed.

2

BAD_PARAMETER

The command failed due to a bad
parameter or command syntax error.


GET AND SET PROPERTY COMMANDS

The Get Property command gets a property from the device. The Get Property command
number is 0.

The Set Property command sets a property in the device. The Set Property command number
is 1.

The Get and Set Property command data fields for the requests and responses are structured as
follows:

Get Property Request Data:

Data Offset

Value

0 Property

ID


Get Property Response Data:

Data Offset

Value

0 – n

Property Value



Set Property Request Data:

Data Offset

Value

0 Property

ID

1 – n

Property Value


Set Property Response Data:
None

The result codes for the Get and Set Property commands can be any of the codes list in the
generic result code table.