Gas connections – Hestan 55 Inch Freestanding Grill Use & Care Guide User Manual

Page 10

Advertising
background image

©2016 Hestan Commercial Corporation

©2016 Hestan Commercial Corporation

16

17

EN

EN

GAS CONNECTIONS

GAS SUPPLY

The local gas authority or supplier should be consulted at the installation planning stage in order

to establish the availability of an adequate supply of gas (NG or LP). If it is a new installation,

have the gas authorities or supplier check the meter size and piping to assure that the unit is

supplied with the necessary amount of gas supply and pressure to operate the unit(s).
Gas connections should be made by a qualified plumber, or your professional outdoor appliance

installer.
All fixed (non-mobile) appliances must be fitted with an accessible upstream gas shutoff valve as

a means of isolating the appliance for emergency shut off and for servicing.
Make certain new piping and connections have been made in a clean manner and have been

purged so that piping compound, chips, etc. will not clog regulators, valves, orifices, or burners.

Use pipe joint compound / thread sealant approved for natural and LP gases.
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY. Before proceeding,

ensure the appliance is fitted for Natural or Liquid Propane gas. Connecting to an improper gas

type will result in poor performance and increased risk of damage or injury. Gas type and gas

consumption (BTU per hour) for each burner type is shown on the rating label affixed to the

underside of the drip tray.
Installation of this cooking appliance must be made in accordance with local codes. In the

absence of local codes, this unit should be installed in accordance with the National Fuel Gas

Code No.

Z223.1/ NFPA 54, Natural Gas and Propane Installation code CSA B149-1, or Propane

Storage and Handling Code B149.2.
NOTE: See rating label for manifold pressure for the type of gas of your appliance.

CONVERSION KITS

Gas conversion kits are available from your Hestan dealer should you need to convert an LP unit

to NG, or vice-versa.

HIGH ALTITUDE KITS

If you live in a high altitude area, 2,000 ft. (610 m) or more above sea level, your grill will require

different orifices for proper combustion and performance. High altitude kits are available

through Hestan Customer Service. Please have your model and serial number information ready

when you call.

GAS CONNECTION - NATURAL GAS (NG)

NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply

pressure is adequate (7.0” WC supply pressure is preferred) to maintain 4.0” WC manifold

pressure. Use a minimum 1/2” ID flex hose to prevent gas starvation. Ensure that the service

pipe supplying the grill is fitted with a shut-off valve conveniently positioned and easily

accessible as an emergency gas shut-off.

Your Hestan grill for use with Natural Gas is supplied with its own regulator which MUST NOT

be removed. If this regulator needs to be replaced, use only the type specified by Hestan for this

appliance.
To connect the regulator / hose assembly follow the next steps:

1. Locate the regulator and gas connection point in the rear right side of your grill (in cart-

mounted models, remove the rear panel to gain access).

2. Install the natural gas regulator as shown. Connect gas supply using a minimum 1/2”

diameter flexible (semi–rigid) stainless steel gas hose, no more than 48” in length. The hose

as well as the connectors must comply with the

Standard for Connectors for Outdoor Gas

Appliances and Manufactured Homes, ANSI Z21.75 • CAS 6.27, and suitable for outdoor

installation. Use the appropriate thread sealant on all connections.

3. Proceed to LEAK TESTING section.

GAS CONNECTIONS

(continued)

Advertising