Hearth and Home Technologies Everest User Manual

Page 22

Advertising
background image

Heat & Glo • Everest • 750-900 Rev. o • 10/08

22

!

Step 4. Positioning, Leveling, and
Securing the Fireplace

The diagram below shows how to properly position, level,
and secure the fi replace.

!

!

Figure 20. Proper Positioning, Leveling, and Securing

of a Fireplace

Figure 21. Intermittent Pilot Ignition

NAILING TABS

(BOTH SIDES)

Step 5. The Gas Control Systems

1. Place the fi replace into position.

2. Level the fi replace from side to side and from front to

back.

3. Shim the fi replace with non-combustible material, such

as sheet metal, as necessary.

4. Secure the fi replace to the framing by nailing or screw-

ing.

Intermittent Pilot Ignition (IPI) System

The gas control system used with this model is Intermittent
Pilot Ignition (IPI).
This system includes a 3V control valve,
electronic module, and intermittent pilot.

WARNING: DIRECT VENT PROPANE MODELS
WITH IPI CONTROL SYSTEMS CANNOT BE
USED IN CANADA.

WARNING: CONTINUOUS 110-120 VAC SER-
VICE MUST BE WIRED TO THE FIREPLACE
JUNCTION BOX.

WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.

Advertising