Heat & Glo • Everest • 750-900 Rev. o • 10/08

24

Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed
electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF
YOU ARE ABSENT FOR EXTENDED TIME PERIODS.
THIS WILL PREVENT ACCIDENTAL FIREPLACE
OPERATION.

Intermittent Pilot Ignition (IPI) Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the
factory installed junction box. Maintain correct polarity when
wiring the junction box.

!

!

Figure 23. Intermittent Pilot Ignition (IPI) Wiring Diagram

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

GRN

ORG

BA

TTER

Y

BACK

UP

SWITCH

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK

ON/OFF

SWITCH

BLACK -

REMOVE BATTERIES
WHEN 3V
TRANFORMER
IS USED

BATTERY

PACK

RED +

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1-#5

LOCATIONS

ON THE

NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BRN

BRN

VALVE

PLUG IN

GROUND TO
FIREPLACE
CHASSIS

I

S

CAUTION: LABEL ALL WIRES PRIOR TO DISCON-
NECTION WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. VERIFY PROPER OPERATION AFTER
SERVICING.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.

Optional Accessories

Optional remote control kits require that 110-120 VAC be
wired to the factory installed junction box before the fi re-
place is permanently installed.

Wall Switch

Position the wall switch in the desired position on the wall.
An assembly of 18 ft of 20 AWG is provided with the fi re-
place to connect the wall switch to the appliance. Instead
of the supplied assembly, wire with a length of 25 ft or less
and a gauge of 20 AWG through 14 AWG is acceptable.
The wire needs a jacket with a temperature rating of 140º
F (60º C) or higher. At the appliance connect the wire to
the ON/OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE GAS CONTROL VALVE OR THE AP-
PLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED

Batteries should not be placed in the battery pack while
using the 3 volt AC transformer. The transformer must be
unplugged if the battery pack is used or battery life will be
reduced.

Advertising