3. remote 14 receptacle information – Hobart Welding Products STELLAR AT OM-2208 User Manual

Page 17

Advertising
background image

OM-2208 Page 13

3-3. Remote 14 Receptacle Information

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

A

J

K

I

24 VOLTS AC

B

Contact closure to A completes 24 volts ac
contactor control circuit.

B

K

I

C

L

N

H

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

C

N

H

D

M

G

E

F

115 VOLTS AC

J

Contact closure to I completes 115 volts ac
contactor control circuit.

C

Output to remote control; 0 to +10 volts dc, +10
volts dc in MIG mode.

REMOTE

D

Remote control circuit common.

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from
remote control.

M

CC/CV select (CC/CV models).

A/V

F

Current feedback; +1 volt dc per 100 amperes.

A/V

AMPERAGE

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 output recep-
tacle volts.

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

*The remaining sockets are not used.

ST-801 245-A

1

115 V 10 A AC Receptacle

Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 3-3).

2

Circuit Breaker CB1

3

Circuit Breaker CB2

CB1 protects duplex receptacle
and 115 volts ac portion of Remote
14 receptacle from overload.

CB2 protects 24 volts ac portion of
Remote 14 receptacle from
overload.

Press button to reset breaker.

2

3

1

3-4. Optional 115 Volts AC Duplex Receptacle And Circuit Breakers

Advertising