3. meter functions for cc/cv model, 4. mode switch settings for cc/cv model – Hobart Welding Products STELLAR AT OM-2208 User Manual

Page 22

Advertising
background image

OM-2208 Page 18

4-3. Meter Functions For CC/CV Model

The meters display the actual weld output values for approximately three seconds
after the arc is broken.

NOTE

Mode

Meter Reading At Idle

Meter Reading While Welding

Scratch

Start TIG

V

A

Actual Volts (OCV)

Preset Amps

80.0

85

Actual Volts

Actual Amps

V

A

10.3

85

Lift-Arc TIG

Actual Volts

Preset Amps

V

A

7.0

85

Actual Volts

Actual Amps

V

A

10.3

85

TIG

Blank

Preset Amps

V

A

85

Actual Volts

Actual Amps

V

A

10.3

85

MIG

Preset Volts

Blank

V

A

24.5

Actual Volts

Actual Amps

V

A

24.5

250

Pulsed

MIG

Pulse Display

Pulse Display

V

A

PPP

PPP

Actual Volts

Actual Amps

V

A

24.5

250

CC

Blank

Preset Amps

V

A

85

Actual Volts

Actual Amps

V

A

24.5

85

Stick

Actual Volts (OCV)

Preset Amps

V

A

80.0

85

Actual Volts

Actual Amps

V

A

24.5

85

V-Sense

Feeder

Flashes OCV And Preset

Blank

V

A

80.0

Actual Volts

Actual Amps

V

A

24.5

250

4-4. Mode Switch Settings For CC/CV Model

The Stick and CC modes provide the Adaptive Hot Start

feature, which

automatically increases the output amperage at the start of a weld should the start
require it. This eliminates electrode sticking at arc start.

NOTE

Mode Switch Setting

Process

Output On/Off Control

Scratch Start TIG

GTAW

Electrode Hot

Lift-Arc TIG

GTAW – See Section 4-7

Electrode Hot

TIG

GTAW With HF Unit, Pulsing Device, Or Remote Control

At Remote 14

MIG

GMAW

At Remote 14

Pulsed MIG

GMAW-P (Requires an external pulsing device.)

At Remote 14

CC

Stick (SMAW) With Remote On/Off

At Remote 14

Stick

SMAW

Electrode Hot

V-Sense Feeder

MIG (GMAW) With Voltage Sensing Wire Feeder

Electrode Hot

Advertising