1. installing welding generator, 2. grounding generator to truck or trailer frame – Hobart Welding Products CHAMP 2060 User Manual

Page 18

Advertising
background image

OM-499 Page 14

SECTION 4 – INSTALLATION

4-1.

Installing Welding Generator

install1 10/00*– 802 524-A / Ref. 151 556 / 158 936-A / S-0854

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Y

Always securely fasten welding
generator onto transport vehicle
or trailer and comply with all DOT
and other applicable codes.

4-2.

Grounding Generator To Truck Or Trailer Frame

install1 10/00* – Ref. 151 556 / S-0854

Y

Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding
Terminal

4

Grounding Cable

Use #10 AWG or larger insulated
copper wire.

Y

If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.

1

2

Electrically bond generator frame to
vehicle frame by metal-to-metal con-
tact.

GND/PE

3

4

2

OR

Advertising