1. maintenance label, 200 h, Engine maintenance – Hobart Welding Products CHAMP 2060 User Manual

Page 28

Advertising
background image

OM-499 Page 24

6-4.

Wiring Instructions For Optional 120/240 Volt Twistlock Plug (NEMA L14-30P)

plug3-11/99 – 802 527

1

Plug Wired For 120/240 V,
3-Wire Load

When wired for 120 V loads, each du-
plex receptacle shares a load with
one half of the 240 V receptacle.

2

Neutral (Silver) Terminal

3

Load 1 (Brass) Terminal

4

Load 2 (Brass) Terminal

5

Ground (Green) Terminal

6

Cord Grip

Strip cord jacket back enough to sep-
arate conductors.

Strip conductors enough to make
good contact with plug terminals.
Make plug connections and reinstall
outer shell and cord grip.

Tighten assembly screws onto shell.
Do not overtighten.

1

3

2

4

Tools Needed:

5

6

120 V

240 V

120V

SECTION 7 – MAINTENANCE

Follow the storage procedure in the engine owner’s manual if the unit will not be
used for an extended period.

NOTE

7-1.

Maintenance Label

Ref. S-175 679-A

ENGINE MAINTENANCE

8 h

1.1 l (1.2 US qt,
1.94 lmp qt)

Unleaded
86 + Octane
6.5 l (1.7 US Gal,
11.4 lmp pt)

50 h

100 h

10W

-30

°

F

+32

+59

+86

+30

+20

+10

0

+40

°

C

+104

-10

-10
-15
-20

200 h

0.7 – 0.8 mm

(0.028 – 0.031 in)

SG-SF/CC-CD

Advertising