3. generator power panel ratings – Hobart Welding Products CHAMP 2060 User Manual

Page 27

Advertising
background image

OM-499 Page 23

6-3.

Generator Power Panel Ratings

Unless otherwise stated, the rating of duplex outlets is the combined load of all
receptacles.

NOTE

Total power from generator NOT to exceed 5500 Watts (60 Hz) or 5000 Watts (50 Hz)

Receptacle

Protected

By

Panel

495 218

(USA)

Panel

495 315

(USA)

Panel

495 219

(USA)

Panel

495 278

(Canada-

CSA)

Panel

495 253

(S. Africa)

Panel

495 288

(South

America)

Panel

495 289

(Australia)

Panel

495 290

(Europe)

Panel

495 283

(S.E. Asia)

60 Hz

60 Hz

60 Hz

60 Hz

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

240 V

Twist Lock

CB1,2

25A/

5500W

See

Note 2

25A/

5500W

See

Note 2

240 V

Duplex

CB1,2

15A/

3600W

See

Note 2

15A/

3600W

240 V

Duplex

CB3,4

15A/

3600W

230 V

Single

CB1

15A/

3600W

15A/

3600W

15A/

3600W

230 V

Single

CB2

15A/

3600W

15A/

3600W

15A/

3600W

230 V

Single

CB1,2

15A/

3600W

230 V

Single

CB3,4

15A/

3600W

120 V

Twist Lock

CB1

30A/

3500W

120 V

Duplex

CB1,3/

CB2,4

30A/

3600W

See

Note 1

120 V

Duplex

CB2

20A/

2400W

120 V

Duplex

CB3

20A/

2400W

20A/

2400W

See

Note 3

20A/

2400W

See

Note 3

120 V

Duplex

CB4

20A/

2400W

See

Note 3

20A/

2400W

See

Note 3

Total

Power NOT

to exceed

5500W

5500W

5500W

5500W

5000W

5000W

5000W

5000W

5000W

For example, for the 495 218 Generator Power Panel,

120V, 3000W heater

3000W

120V, 10A chain saw

1200W

120V, 500W halogen lamp

500W

Total

4700W

This loading is OK.

120V, 3000W heater

3000W

120V, 10A chain saw

1200W

120V, 5A router

600W

120V, 1000W halogen lamp

1000W

Total

5800W

This loading is not OK.
It exceeds 5500W.

Notes: 1. Each receptacle of the duplex can provide 15A/1800W. Do not parallel the two 120V duplex receptacles.

2. Do not parallel the two 120V circuits.
3. Do not parallel the two duplex outlets.

Calculating total power provided by generator.
(See Section 10 – Generator Power Guidelines)

Each receptacle can provide the watts or amps as shown
above. However, the total power can not exceed 5500W.

The rating plate on electrical apparatus will contain the watts
consumed or the rated input amps. Watts may be calculated by
multiplying the rated voltage by the rated input amps.

watts = volts x amps

Advertising