Hearth and Home Technologies GBST4336I User Manual

Page 19

Advertising
background image

19

Heatilator • GBST4336I, GBFL4136I • 2135-900 Rev. D • 11/08

C

A

B

D

* Adjust framing dimensions for interior sheathing (such as sheetrock)
**See pipe manufacturer’s installation instructions

MINIMUM FRAMING DIMENSIONS*

GBFL4136I

A

B

C*

D

E

F

G

H

I

Rough

Opening

(Vent Pipe)

Rough

Opening

(Height)

Rough

Opening

(Depth)

Rough

Opening

(Width)

Clearance

to Ceiling

Combustible

Floor

Combustible

Flooring

End of

Appliance

Sides of

Appliance

Inches

**

38-1/8

23

40

31-5/8

0

0

1/2

36

Millimeters

**

968

584

1016

803

0

0

13

914

E

G

H

I

F

I

Figure 5.3 Clearances to Combustibles, Model GBFL4136I