Heatilator • GBST4336I, GBFL4136I • 2135-900 Rev. D • 11/08

Figure 13.16 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

TOP VIEW

3-1/4 in. Min.

2-3/4

in. Min.

1/2 in.

Min.

Unlimited

1 in.
Max.

FIREPLACE

OPENING

Note: Clearance from
opening to perpendicular
wall.

C. Facing Material

• Metal front faces may be covered with non-combustible

materials only.

• Facing and/or fi nishing materials must not interfere with

air fl ow through louvers, operation of louvers or doors,
or access for service.

• Facing and/or fi nishing materials must never overhang

into the glass opening.

• Observe all clearances when applying combustible

materials.

• Seal joints between the fi nished wall and appliance top

and sides using a 300 °F minimum sealant. Refer to
Figure 13.17.

WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.

0 in.

0 in.

0 in.

Finish wall material may be
combustible - Top and Sides

High Temperature Sealant (300° F/149° C min.)

Top and Side Seal Joint

Figure 13.17 Noncombustible Facing Diagram

Combustible Mantel Legs or Wall Projections