E. junction box installation – Hearth and Home Technologies GBST4336I User Manual

Page 31

Advertising
background image

31

Heatilator • GBST4336I, GBFL4136I • 2135-900 Rev. D • 11/08

RED

VALVE

TRANSFORMER 3V

BLACK

BROWN

GROUND TO
FIREPLACE CHASSIS

TEMP SENSOR

BATTERY PACK

ORG

GREEN

BROWN

PLUG-IN

BLACK

BLACK

REMOTE RECEIVER

PLUG IN

WHITE

ORANGE

IGNITION

MODULE 3 VAC

INTERMITTENT

PILOT IGNITOR

I

S

Figure 12.2 Intellifi re Ignition Wiring Diagram with Remote Receiver

ROMEX CONNECTORS

Figure 12.3 Junction Box Detail

NOTICE: DO NOT wire
110 VAC to wall switch.

E. Junction Box Installation

The junction box must be wired from the INSIDE of the
appliance:

• Determine which side of the appliance the junction box

is located on.

• Pull the electrical wires from outside the appliance through

the knockout making sure to use a Romex connector to
fasten the electrical wires to the unit.

• Pull enough wire into the valve compartment to easily reach

the junction box location.

• Remove the screw attaching the junction box to the junction

box bracket and set it aside.

• Route the wire through the knockout in the junction box

bracket.

• Wire the junction box and reattach it to the bracket by

inserting the tab in the slot and attaching with screw
previously removed. Ensure that a Romex connector is
used to attach the electrical wires to the junction box.