Hearth and Home Technologies BIR42 User Manual

Page 18

Advertising
background image

18

B. Clearances

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specifi ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.

Heatilator • Birmingham BIR42 • 4059-308 Rev E • 08/08

(insulation)

Attic

Insulation

Shield

(ceiling)

(roof)

(attic)

(ceiling)

Ceiling Firestop

Offset/Return (secured

with hanger straps)

Storm Collar

Roof Flashing

1-1/2 in. (38 mm) to back &

sides of appliance

(except at nailing flanges

where it is 1/2 in. [13 mm])

Must have 2 in. (51 mm)

minimum clearance

to header

0 in.

to floor

2 in. (51 mm) min.

Shaded areas

represent

2 in. (51 mm) min.

air space clearance

required around pipe

Combustible Object

48 in.

1219 mm

Transition

Figure 6.2 Air Space Clearances

Advertising