Figure 8.4 Assembling Chimney Sections

• Support the pipe during construction and check to be sure

inadvertent loading has not dislodged the chimney section
from the fi replace or at any chimney joint.

• Attach a straight chimney section or an offset to the top

of the fi replace.

• Place

inner

fl ue to the inside of the chimney section below

it. Place the outer casing outside the outer casing of the
chimney section below it. Refer to Figure 8.4.

NOTICE:

Chimney sections cannot be disassembled once

locked together. Plan ahead!

• Lock chimney sections and/or offsets/returns together by

pushing downward until the top section meets the stop
bead on the lower section.

• Pull on the top section to make sure it is fully engaged

and will not separate.

• You may use #6 or #8 sheet metal screws no longer than

1/2 in. (13 mm) to fasten chimney sections together. Do
NOT penetrate inner fl ue.

WARNING! Risk of Fire! You MUST use screws (pro-
vided) to fasten offset/returns to chimney sections to
keep the chimney parts from twisting. Failure to do so
could cause fi re.

• Fasten offset/returns to chimney sections. Insert the

screws (provided) through the predrilled holes. Do NOT
penetrate inner fl ue.

• Secure chimney returns with hanger straps (provided);

fasten to studs or joists.

• Vertical straight runs of chimney must be supported every

35 ft (10.7 m).

C. Assemble Chimney Sections

WARNING! Risk of Fire! DO NOT install substitute or dam-
aged chimney components.
• Use only those components described in this manual.
Substitute or damaged chimney components could impair
safe operation and cause overheating and fi re.