Raised hearth extension framing – Hearth and Home Technologies BIR42 User Manual

Page 41

Advertising
background image

41

IMPORTANT! Hearth extension design must be determined
before installation of fi replace.

Floor

Noncombustible

Framing Material

Noncombustible

Finishing Material

Protective Metal

Hearth Strips

1 in. Micore or

equivalent insulation

& 1/2 in. Durock

Bottom of

fireplace opening

Note: The bottom of the
fireplace opening is 3-3/4 in.
(95.3mm) above the bottom of
the fireplace. Finished hearth
must NOT extend above this
level.

Platform must be built
to raise the bottom of
the fireplace opening
to the level of the
desired hearth height.

20 in. Min.

Hearth Extension

Figure 12.3 Raised Platform Hearth Extension Detail

Raised Hearth Extension Framing

The hearth framing must be constructed of non-combus-
tible materials (Figure 12.2) and placed on 1/2 in. Durock
and 1 in. Micore (or equivalent material) (Figure 12.4).
When creating the platform, allow for the thickness of the
non-combustible fi nishing materials (Figure 12.5).

Noncombustible
Framing Material

1 in. Micore or

equivalent insulation

& 1/2 in. Durock

Figure 12.4 Raised Platform Hearth Extension-Framing Materials

Noncombustible
Finishing Materials

Figure 12.5 Raised Platform Hearth Extension-Finishing Materials

* 2 in. (51 mm)

Continuous,
non-combustible sealant

Tile, stone or other
non-combustible material

Floor constructed of wood or
other combustible material

1 in. Micore or
equivalent insulation
(see Table)

Fireplace

Protective
Metal Hearth
Strip

Durock

*

*

Figure 12.2 Hearth Extension Construction

Heatilator • Birmingham BIR42 • 4059-308 Rev E • 08/08

Advertising