Non-combustible Sealant

After completing the framing and applying the facing mate-
rials over the framing, a bead of non-combustible sealant
must be used to close off any gaps at the top and sides
between the fi replace and hearth.

Non-combustible Sealant

Note: The bottom of the fireplace
opening is 3-3/4 in. (95.3mm) above
the bottom of the fireplace. Finished
hearth must NOT extend above this
level.

Noncombustible Finishing Material

Protective Metal

Hearth Strip

30 in. Min.

Hearth Extension

1 in. (25.4 mm)

Micore and

1/2 in. (13 mm)

Durock

Finished

Floor

Bottom of

Fireplace Opening

Figure 12.7 Flush Hearth Extension

Flush Hearth Extension Framing

• Fireplace must be recessed 3 3/4 in. (95.3 mm) below the

fi nished fl oor.

• Refer to Figures 12.7 and 12.8.

Figure 12.8 Flush Hearth Extension Side View

Figure 12.6 Place Non-combustible Sealant

Heatilator • Birmingham BIR42 • 4059-308 Rev E • 08/08