Footnotes for the preceding tables and the table on the following page:

*1: The protection method conforms to JEM 1030.

*2: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). To use other

motors, care must be taken to prevent the rated motor current (50/60 Hz) from exceeding the
rated output current of the inverter.

*3: The output voltage decreases as the main supply voltage decreases (except for use of the

AVR function). In any case, the output voltage cannot exceed the input power supply
voltage.

*4: To operate the motor beyond 50/60 Hz, consult the motor manufacturer about the maximum

allowable rotation speed.

*5: The braking torque via capacitive feedback is the average deceleration torque at the shortest

deceleration (stopping from 50/60 Hz as indicated). It is not continuous regenerative braking
torque. And, the average deceleration torque varies with motor loss. This value decreases
when operating beyond 50 Hz. Note that a braking unit is not included in the inverter. If a
large regenerative torque is required, the optional regenerative braking unit should be used.

*6: The frequency command is the maximum frequency at 9.8V for input voltage 0 to 10 VDC,

or at 19.6 mA for input current 4 to 20 mA. If this characteristic is not convenient for your
application, contact your Hitachi sales representative.

*7: If operating the inverter in an ambient temperature of 40–50

°

C, reduce the carrier frequency

to 2.1 kHz, derate the output current by 80%, and remove the top housing cover. Note that
removing the top cover will nullify the NEMA rating for the inverter housing.

*8: The storage temperature refers to the short-term temperature during transport.

*9: Conforms to the test method specified in JIS C0911 (1984). For the model types excluded in

the standard specifications, contact your Hitachi sales representative.

*10:The input voltage of xxLFU is 230V.

Item

400V Class Specifications

L100 inverters, 400V models

004HFE

004HFU

007HFE

007HFU

015HFE

015HFU

022HFE

022HFU

030HFE

—

040HFE

040HFU

055HFE

055HFU

075HFE

075HFU

Applicable motor size *2

kW

0.4

0.75

1.5

2.2

3.0

4.0

5.5

7.5

HP

1/2

1

2

3

4

5

7.5

10

Rated capacity (460V) kVA *10

1.1

1.9

3.0

4.3

6.2

6.8

10.4

12.7

Rated input voltage

3-phase: 380 to 460V ±10%, 50/60 Hz ±5%

Rated input current (A)

2.0

3.3

5.0

7.0

10.0

11.0

16.5

20.0

Rated output voltage *3

3-phase: 380 to 460V (corresponding to input voltage)

Rated output current (A)

1.5

2.5

3.8

5.5

7.8

8.6

13

16

Braking

Dynamic braking,
approx. % torque,
(short time, stopping
from 50 / 60 Hz) *5

100%:

≤

50Hz

50%:

≤

60Hz

40%:

≤

50Hz,

20%:

≤

60Hz

20%:

≤

50Hz

20%:

≤

60Hz

Capacitive feedback type, dynamic braking unit and braking resistor optional,
individually installed

DC braking

Variable operating frequency, time, and braking force

Weight

kg / lb

1.3/2.9

1.7/3.7

1.7/3.7

2.8/6.2

2.8/6.2

2.8/6.2

5.5/12.1 5.7/12.5