DC Braking Settings

The DC braking feature provides
additional stopping power when compared
to just a normal deceleration to a stop. DC
braking is particularly useful at the low
frequency end of the deceleration ramp
where there is little or no motor torque
available for stopping. If you enable DC
braking, it turns on during deceleration at a
frequency you can specify. If desirable,
you can specify a delay time during which the motor coasts (free runs) before DC
braking helps stop the rotation.

Most importantly, the force and duration of DC braking are adjustable. Be careful to not
specify a long braking time that causes motor overheating. If you use DC braking, we
recommend using a motor with a built-in thermistor, and wiring it to the inverter’s
thermistor input (see page 4–17). Also refer to the motor manufacturer’s specifications
for duty-cycle recommendations during DC braking.

DC braking

A53

A55

Free run

Running

+

0

time

“A” Function

Run-

time
Edit

Defaults

DOP,DRW,DOP+

Func.

Code

Name

Description

EU/

US

Units

Func.

Code

Name

A51

DC braking enable

Two options; select codes:
00... Disable
01... Enable

00

F-20

DCB SW

A52

DC braking frequency
setting

The frequency at which DC
braking occurs,
range is 0.5 to 10 Hz

0.5

Hz

F-20

DCB F

A53

DC braking wait time

The delay from the end of Run
command to start of DC
braking (motor free runs until
DC braking begins)

0.0

sec.

F-20

DCB
WAIT

A54

DC braking force
setting

Applied level of DC braking
force, settable from 0 to 100%

0

%

F-20

DCB V

A55

DC braking time
setting

Sets the duration for DC
braking, range is 0.1 to 60.0
seconds

0.0

sec.

F-20

DCB T