Hitachi L100 User Manual

Page 70

Advertising
background image

“A” Group: Standard Functions

Conf

igur

in

g

Dr

iv

e P

a

ra

m

e

ter

s

3–14

The following table shows the methods of torque control selection.

“A” Function

Run-

time
Edit

Defaults

DOP,DRW,DOP+

Func.

Code

Name

Description

EU/

US

Units

Func.

Code

Name

A41

Torque boost method
selection

Two options:
00 ...Manual torque boost
01 ...Automatic torque boost

00

F-50

V-BOOST
MODE

A42

Manual torque boost
value

Can boost starting torque
between 0 and 99% above
normal V/F curve, from 0 to
1/2 base frequency

11

F-50

V-BOOST
CODE

A43

Manual torque boost
frequency adjustment

Sets the frequency of the V/F
breakpoint A in graph (top of
previous page) for torque boost

10

%

F-50

V-BOOST
F

A44

V/F characteristic
curve selection

Two available V/F curves;
three select codes:
00 ...Constant torque
01 ...Reduced torque

0

F-04

Control

A45

V/F gain setting

Sets voltage gain of the inverter
from 20 to 100%

100

%

Mon.

V-GAIN

Technologies Inc.

Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com

Advertising