Fig. 4—T8611G 2-stage heat/1-stage cool thermostat.

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

DENOTES THERMOSTAT TO SUBBASE INTERCONNECT.

POSSIBLE CHECK LED CIRCUITS:

M 6020

MONITOR

AUXILIARY
HEAT RELAY

HEAT 2

L1
(HOT)

L2

HEAT

OFF

AUTO

SYSTEM
SWITCH

AUTO

ON

FAN
SWITCH

1

EMERGENCY
HEAT RELAY

FAN RELAY

CHANGEOVER
RELAY (HEAT)

COMPRESSOR
CONTACTOR

EM. HT.

CHANGEOVER
RELAY (COOL)

AUX. HEAT
LED (GRN)

EM. HEAT
LED (RED)

HEAT 1

THERMOSTAT
LOGIC
CIRCUIT

SUBBASE
LOGIC/
CONTROL
CIRCUIT

R

C/X

L

W2

E

X2

G

O

B

Y

POWER
SUPPLY

HIGH
LIMIT

HIGH
LIMIT

X1

2

1

2

3

COOL

C.O.

C.O.

COOL

CHECK LED
(YELLOW)

CHECK
LED
(YELLOW)

FAULT DETECTION
SWITCH

SWITCH TO R (POWER) SIDE OF
SYSTEM TRANSFORMER

TO R

TO C/X

CHECK
LED
(YELLOW)

FAULT DETECTION
SWITCH

SWITCH TO C (COMMON) SIDE
OF SYSTEM TRANSFORMER

TO R

TO C/X

CHECK
LED
(YELLOW)

SWITCHING
DEVICE

SWITCH IN SECONDARY OF
SEPARATE TRANSFORMER

L1
(HOT)

L2

24 Vac

1

X1

X2

X1

X2

X1

X2

3

3

69-0348—1

Advertising