Honeywell CHRONOTHERM III T8611G User Manual

Page 5

Advertising
background image

5

69-0348—1

Fig. 6—T8611R 2-stage heat/1-stage cool thermostat. Exact replacement for York model no. 2ET11700224.

MONITOR

AUXILIARY
HEAT RELAY

HEAT 2

L1
(HOT)

L2

HEAT

OFF

AUTO

SYSTEM
SWITCH

AUTO

ON

FAN
SWITCH

1

STAGE 1
HEAT RELAY

EMERGENCY
HEAT RELAY

FAN RELAY

CHANGEOVER
RELAY (HEAT)

COMPRESSOR
CONTACTOR

EM. HT.

COOL

CHANGEOVER
RELAY (COOL)

EM. HEAT
LED (RED)

HEAT 1

THERMOSTAT
LOGIC
CIRCUIT

SUBBASE
LOGIC/
CONTROL
CIRCUIT

R

B

X

W2

E

W1

G

O

H

Y1

TRANSFORMER

POWER
SUPPLY

HIGH
LIMIT

HIGH
LIMIT

2

3

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

REMOVE JUMPER FOR SYSTEM WITH ISOLATED STAGE 1 HEATING
AND COOLING CONNECTIONS.

DENOTES THERMOSTAT TO SUBBASE INTERCONNECT.

REMOVE JUMPER FOR SYSTEM WITH ISOLATED EMERGENCY HEAT.

TRANSFORMER COMMON IS CONNECTED TO B TERMINAL.

1

2

3

4

5

4

5

M3206

NOTE: THIS DIAGRAM IS FOR USE WHEN REPLACING ONLY YORK
THERMOSTAT MODEL NO. 2ET11700224. USING THIS
DRAWING FOR OTHER INSTALLATIONS CAN RESULT IN
DAMAGE TO THERMOSTAT.

Fig. 8—Battery placement.

Fig. 7—Cycle rate adjustment.

CYCLE RATE ADJUSTMENT

To custom-tailor the thermostat’s cycling performance to

different types of heating equipment, a cycle rate adjustment
screw is provided on the back of the thermostat. Correct
setting of this screw will provide optimum savings.

NOTE: Most applications will not require a change in

cycle rate.

The room air temperature will normally vary slightly from

the comfort temperature setting with the cycling of the heat
pump or auxiliary heater.

The cycle rate of this thermostat is factory-set for heat

pumps. The heat pump compressor cycle rate can be adjusted
by turning the cycle rate adjustment screw located on the back
of the thermostat, see Fig. 7.

INSTALLING BATTERIES

Three AAA alkaline batteries are provided as backup to

prevent program loss in event of power outage. Batteries are
included with thermostat. Install batteries in back of thermo-
stat as shown in Fig. 8.

Without battery backup, the program will remain about 20

seconds in event of power loss. When batteries are first
installed, the display will flash 1:00 PM and 32

°.

BATTERY PLACEMENT
(NOTE CORRECT PLUS
AND MINUS DIRECTION)

M372A

Advertising
This manual is related to the following products: