h. Firebox Bottom Removal

1) Shut off the gas to the appliance before

removing. Remove the glass frame following

instructions found in Step 3a. on page 7.

2) Remove the two screws on the log assembly

(Figure 20). Pull out the log assembly (Figure

21) and place in a safe area. Remove the

four screws located around the firebox

bottom. See Figure 22.

3) To re-install the firebox bottom, reverse the

above steps.

Figure 20 - Log Assembly Removal

Figure 21 - Log Assembly Removal

Figure 22 - Firebox Bottom Removal

Figure 23 - Fan Removal

i.

Fan Access
1) Disconnect the power cord or turn off the

circuit breaker before removing the fan.

Remove the firebox bottom following

directions in Step 3h.

2) Remove the four screws located on the fan

bracket (Figure 23). Remove two on the fan

control. Remove the bushing and unplug the

cord from the junction box. Slide the fan

bracket out.

3) To re-install fan, reverse the above steps.

WARNING!

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating this appliance.