GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT

Seal with high temperature silicone at the point where

the gas line enters the existing fireplace to prevent

cold air infiltration.

This fireplace has been altered to

accommodate an insert and should be

inspected by a qualified service technician

prior to re-use as a conventional fireplace.

Note:

The above label, located in the instruction

package, must be affixed to the existing fireplace prior

to installation of the GBi25 Gas Fired Fireplace Insert.

3. APPLIANCE INSTALLATION

a. Firebox Entry

To gain access to the draft hood, remove the two

screws located in the upper corners of the glass

frame. See Figure 2.

Figure 2 - Firebox Entry

Figure 3 - Glass Frame Removal

Rotate glass frame forward and lift out. See

Figure 3.

Handle the glass frame with care to avoid striking

or scratching it on hard objects or slamming it

shut.
Remove the two screws on the baffle, as shown

in Figure 4. To remove the draft hood, unscrew

the four screws located around the exhaust

opening. See Figure 5. Slide the draft hood out of

the appliance and attach draft hood to flex liner in

appliance with a minimum of three sheet metal

screws. A 4” diameter hose clamp may also be

used. See Figure 6.
The draft hood must be installed so as to be in

the same atmospheric pressure zone as the

combustion air inlet to the appliance and shall

be located so that the relief opening is accessible

for checking vent operation.
Pack the area at the damper with noncombustible

insulation to prevent cold air infiltration into the

fireplace cavity.

Figure 4 - Baffle Removal

Figure 5 - Draft Hood Removal

Figure 6 - Draft Hood Attachment