Wiring, Gbi25 series b-vent gas fired fireplace insert – Hearth and Home Technologies GBI25 User Manual

Page 12

Advertising
background image

26678 Rev H

12

02-02

GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT

4. WIRING

a. A 110V AC outlet should be located close to the

lower left side of the appliance to allow the fan to

be plugged in. See Figure 24.

Figure 24 - Wiring Diagram

Note:

This appliance REQUIRES a 110V AC

supply for operation of the fan.

Note:

This appliance must be electrically wired and

grounded in accordance with local codes or, in the ab-

sence of local codes, with National Electric Code ANSI/

NFPA 70-latest edition. This appliance can be used with

a thermostat.

CAUTION:

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and danger-

ous operation. Verify proper operation after servicing.

WARNING!

Do not use this appliance if any part has been under water. Immediately call a qualified

service technician to inspect the appliance and to replace any part of the control sys-

tem and any gas control which has been under water.

Advertising