A. listings and code aprovals, B. description of the system, Building supplies – Hearth and Home Technologies GBI25 User Manual

Page 3: Certification, Description of the system, Fuel, Listings and code aprovals, Local codes, Negative air locations, Sealant material

Advertising
background image

02-02

3

26678 Rev H

GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT

A. LISTINGS AND CODE APROVALS

U.S. AND CANADA CERTIFICATION

This appliance has been tested in accordance with ANSI

Z21.11.1-1991, CAN/CGA 1-2.1-MB6 and applicable

sections of ANSI Z21.50-1996 CAN/CGA 2.22-M96 and

has been LISTED by Underwriters Laboratories Inc. for

installation and operation as described in these

Installation and Operating Instructions. All components

are UL. AGA, CGA or CSA safety certified.

LOCAL CODES

Check with your local building code agency prior to

installing this appliance to ensure compliance with local

codes, including the need for permits and follow-up

inspections. This installation must conform with local

codes or, in the absence of local codes, with the National

Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.

and the CANI-B149-latest edition in Canada. The

appliance, when installed, must be electrically grounded

in accordance with local codes; in the absence of local

codes, with the current National Electric Code ANSI/FNPA

No. 70 (in the U.S.A.) or with the current CSA C2.1 Canadian

Electric Code in Canada.

FUEL

Any additions, changes or conversions required in order

for the appliance to satisfactorily meet the application

needs, must be made by a qualified service technician

using factory specified and approved parts.
If you require assistance during installation, please contact

your local dealer or the Heatilator Technical Services

Department, Hearth Technologies Inc., 1915 W. Saunders

Street, Mt. Pleasant, Iowa 52641 (1-800-843-2848).
HEATILATOR® is a registered trademark of Hearth

Technologies Inc. (HTI), a division of HON INDUSTRIES.

B. DESCRIPTION OF THE SYSTEM

The GBi25 Series is a B-vent gas-fired room heater.

Combustion air is supplied from inside the house.
This HEATILATOR system must consist of the following:

1. Appliance
2. B-Vent Venting System
3. Termination
4. Surround

HIGH TEMPERATURE SEALANT MATERIAL

Sealants that will withstand high temperatures: General

Electric RTV103 (Black), or equivalent. Rutland, Inc.

Fireplace Mortar #63 or equivalent; Dow Corning 732 or

equivalent.

We strongly recommend that you DO NOT install B-Vent

Gas Appliances in strong negative air locations, such

as a basement or a public facility. Living rooms with

cathedral ceilings could be susceptible to a negative

air situation, but such installations can be overcome

through raising the termination, depending on specific

installations. This fireplace uses room air for normal

operation and could have problems establishing a

positive draft in negative air locations. In lieu, we

recommend a direct vent appliance.

Note:

Illustrations throughout these instructions reflect

typical installations and are for design purposes only.

Actual installation may vary slightly due to individual

design preferences. However, minimum and maximum

clearances must be maintained at all times.
The illustrations and diagrams used throughout these

installation instructions are not drawn to scale.

Tools and building supplies normally required for

installation:

Saw

Wall-finishing materials

Pliers

Framing material

Hammer

Surround

Phillips screwdriver

Caulking material

Tape measure

Safety gloves

Plumb line

Electric drill/bits

Level

Framing Square

Advertising