B. clearances – Hearth and Home Technologies Indoor/Outdoor Gas Fireplace Twilight-II-B User Manual

Page 18

Advertising
background image

Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. M • 11/08

18

H

K

G

F

J

I

Figure 5.3 Clearances to Combustibles

Note: Framing dimensions assume use of
1/2 inch thick wall covering materials on
exterior of framing only, and NO sheetrock
on interior of framing.

From top of hood to
ceiling (interior) or
overhang (exterior).

Figure 5.2 Exterior View - Minimum Clearances

Vinyl

Non-vinyl

A

36 in.

12 in.

B

64-5/16 in.

35-5/16 in.

OVERHANG

A

A

B

SIDING

SIDING

SIDING

FINISHING MATERIALS

A

INTERIOR
FRAMING

EXTERIOR
FRAMING

E

D

C

A

B

B. Clearances

NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.

WARNING! Risk of Fire! Do not install appliance against
vapor barriers or exposed insulation. Prevent contact with
sagging or loose insulation.

• Locate and install appliance to all clearance specifi cations

in manual.

• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and
making contact with fi replace.

• Failure to maintain airspace may cause overheating and

a fi re.

CLEARANCES TO COMBUSTIBLES:

A

B

C

D

E

F

G

H

I

J

K

Exterior

Rough

Opening

(Height)

Interior

Rough

Opening

(Height)

Rough

Opening

(Depth)

Rough

Opening

(Width)

Framing

for non-

combustible

material

Clearance

to Ceiling

(INT)

Clearance to Overhang

(EXT)

Combustible

Floor

Combustible

Flooring

Standoff

Height

Inside

Standoff

Height

Outside

Sides of

Appliance

Non-Vinyl

Vinyl

Inches

49-1/4

41-1/4

23

44

46-1/8

35-3/4

35-5/16

64-5/16

0

0

3-3/8

9-1/2

1/2

mm

1251

1048

584

1118

1172

908

897

1634

0

0

86

241

13

Note: Verify that tabs on insulation bracket are in an upright
position.

Advertising