Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. M • 11/08

6

B. Tempered Glass Specifi cations

Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as defi ned by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certifi ed to the requirements
of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing
Certifi cation Council SGCC# 1595 and 1597. Architectur-
al Testing, Inc. Reports 02-31919.01 and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5
“Certifi cation and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”

Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.

This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.

A. Appliance Certifi cation

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.

NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.

1

1

Listing and Code Approvals

E. BTU Specifi cations

MODEL: Twilight-II-B
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Gas Appliance
STANDARD:
ANSI Z21.50-2003 • CSA2.22-M03 • UL307B

D. Air Infi

ltration, Water Resistance and

Structural Tests

T

he Hearth & Home Technologies Twilight-II-B Indoor/

Outdoor Appliance unit was tested to the following ASTM
standards at the Stork Twin City Testing laboratory.

Air infi ltration test ASTM:E283-(04). The sample was test-
ed at 1.57 psf (equivalent to a 25-mph windload). Water
resistance test ASTM:E331-00. The test specimen was
tested at the requested test pressures of 8.0 & 25.0 psf.

Structural test ASTM:E330-02. The unit was tested to a
design pressure of 50-psf, a test pressure of 75-psf.

Test Results

C. Thermal Performance Data

Model: Twilight-II-B

Sound Transmission

Class (STC)

Thermal Resistance

(R Value)

Thermal Conductivity

(K Value)

27

0.8hr-sq ft-ºF/BTU

1.25 BTU-in/hr-sq ft-ºF

Model

U.S. (0-2000 FT) or

Canada (2000-4500 FT)

Input

BTU/h

Orifi ce Size

(DMS)

Twilight-II-B (NG)

US

38,000

32

CAN

34,200

33

Twilight-II-B (LP)

US

37,000

50

CAN

33,300

51

Model

Air Infi ltration

(ASTM E283)

Water Resistance

(ASTM E331)

Structural Load

(ASTM E330)

Twilight-II-B

Indoor/Outdoor

0.07CFM/ft2

No leakage

@ 8psf & 25psf

No Blowout

@ 75psf