31

Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. M • 11/08

Figure 10.5 Exterior View

Fire Risk.

Finish all edges and fronts to clearances
and specifi cations listed in manual.

• Black metal columns may be covered with

non-combustible material only.

• Do NOT overlap combustible materials onto appliance

front.

• Install combustible materials only up to specified

clearances on top, front and side edges.

• Seal joints between the fi nished wall and appliance top

and sides using only a 300º

F minimum sealant.

May install non-combustible materials to cover gap be-
tween facing material and appliance (see Figure 10.5).

Fire Risk.

Water Intrusion Risk.

Hood is required.

• Flashing and non-combustible sheathing must be

installed before facing materials.

• Facing must be non-combustible and seal tight to

fi replace front.

Risk of Fire

• Non-combustible clearances must be

maintained.

• Sheetrock, wood or other combustibles must NOT

be used as sheathing or facing in the non-
combustible zone.

• See Sections 3 & 8 for proper clearances.

• See Section 1 for combustible/non-

combustible defi nitions.

2-3/4 in.

12 in.

HOOD

NON-COMBUSTIBLE

SHEATING

6 in.

MAX.

NON-COMBUSTIBLE

FACING

THERE MUST BE NO GAP
BETWEEN BRICK LEDGE,

FACING MATERIAL AND

APPLIANCE FRONT.

6 in. MAXMUM PROJECTION

FROM FACE OF FIREPLACE

BRICK LEDGE

NON-COMBUSTIBLE

SHEATHING

(SUPPLIED)

COMBUSTIBLE

SHEATHING

HOUSEWRAP

REQUIRED

FLASHING

(SUPPLIED)

HOUSE
WRAP

WARNING