C. intellifi re ignition system wiring – Hearth and Home Technologies Indoor/Outdoor Gas Fireplace Twilight-II-B User Manual

Page 27

Advertising
background image

27

Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. M • 11/08

Figure 9.3 Intellifi re Pilot Ignition (IPI) Wiring Diagram

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts.
Uninterrupted 120 VAC is required at junction box unless equipped with battery back-up.

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

GRN

ORG

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK

ON/OFF SWITCH

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1-#5

LOCATIONS

ON THE

NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BRN

BRN

VALVE

PLUG IN

GROUND TO
FIREPLACE
CHASSIS

I

S

C. Intellifi re Ignition System Wiring

• Wire the appliance junction box to 110 VAC for proper

operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.

• Refer to Figure 9.2, Intellifi re Pilot Ignition (IPI) Wiring

Diagram.

• This appliance is equipped with an Intellifi re control valve

which operates on a 3 volt system.

• Plug the 3-volt AC transformer into the appliance junction

box to supply power to the unit OR install two D cell
batteries (not included) into the battery pack before use.

NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries before
using the transformer, and unplug the transformer before
installing the batteries. Battery polarity must be correct or
module damage will occur.

Advertising