Hitachi CP-X10000 User Manual

Page 54

Advertising
background image

54

OPTION menu

Item

Description

SERVICE

(continued)

COMMUNICATION

(continued)

RESPONSE LIMIT TIME

This menu is available only when the NETWORK

BRIDGE is selected for the COMMUNICATION

TYPE and the HALF-DUPLEX is selected for the

TRANSMISSION METHOD.

Select the time period to wait for receiving response

data from other devise communicating by the

NETWORK BRIDGE and the HALF-DUPLEX through

the CONTROL OUT port.

OFF ó 1s ó 2s ó 3s

OFF: Select this mode if it is not required to check the

responses from the devise that the projector sends data

to. In this mode, the projector can send out data from

the computer continuously.

1s/2s/3s: Select the time period to keep the projector

waiting for response from the device that the projector

sends data to. While waiting the response, the projector

does not send out any data from the CONTROL OUT

port.

BYTES INTERVAL TIMEOUT

This menu is available only when NETWORK BRIDGE

is selected for the COMMUNICATION TYPE and HALF-

DUPLEX is selected for the TRANSMISSION METHOD.

Select the blank time length to judge that the response

data has finished in the communicating in the condition

of the NETWORK BRIDGE and the HALF-DUPLEX

through the CONTROL OUT port.

50ms ó 100ms ó 150ms ó 200ms

• 50ms is selected as the default setting.

NOTE

• OFF is selected as the default setting.

NOTE

Advertising
This manual is related to the following products: