Troubleshooting

Regarding the indicator lamps

Lighting and blinking of the POWER indicator, the TEMP indicator, the LAMP
indicator, the SECURITY indicator and the SHUTTER indicator have the meanings
as described in the table below. Please follow the instructions within the table. If
the same indication is displayed after the remedy, or if an indication other than the
following is displayed, please contact your dealer or service company.

(Continued on next page)

POWER

TEMP

LAMP

SECURITY

SHUTTER

Description

Lighting

In

Orange

Turned

off

Turned

off

Turned

off

Turned

off

The projector is in a standby state.

Please refer to the section “Turning on/off”.

Blinking

In

Green

Turned

off

Turned

off

Turned

off

Turned

off

The projector is warming up.

Please wait.

Lighting

In

Green

Turned

off

Turned

off

Turned

off

Turned

off

The projector is in an on state.

Ordinary operations may be performed.

Blinking

In

Orange

Turned

off

Turned

off

Turned

off

Turned

off

The projector is cooling down.

Please wait.

Turned

off

Turned

off

Turned

off

Blinking

In

Red

Turned

off

The PIN Lock or (and)

TRANSITION DETECTOR is (are) on.

Please refer to the description

(

63,64).

Turned

off

Turned

off

Turned

off

Turned

off

Blinking

In

Yellow

The SHUTTER is closed.

Please refer to the description

(

26).

Blinking

In

Red

(discre-
tionary)

(discre-
tionary)

Turned

off

Turned

off

The projector is cooling down. A certain error has

been detected.

Please wait until the POWER indicator finishes blinking,
and then perform the proper measure using the item
descriptions below.

Blinking

In

Red

or

Lighting

In

Red

Turned

off

Lighting

In

Red

Turned

off

Turned

off

The lamp does not light, and there is a possibility

that interior portion has become heated.

Please turn the power off, and allow the projector to
cool down at least 20 minutes. After the projector has
sufficiently cooled down, please make confirmation of
the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the remedy, please
change the lamp referring to the section “Lamp unit”.

Blinking

In

Red

or

Lighting

In

Red

Turned

off

Blinking

In

Red

Turned

off

Turned

off

The lamp cover has not been properly fixed.

Please turn the power off, and allow the projector to
cool down at least 45 minutes. After the projector has
sufficiently cooled down, please make confirmation of
the attachment state of the lamp cover. After performing
any needed maintenance, turn the power on again. If the
same indication is displayed after the remedy, please
contact your dealer or service company.