HP 5400ZL User Manual

Page 222

Advertising
background image

Switch Meshing
Operating Notes for Switch Meshing

Connecting Mesh Domains:

To connect two separate switch meshing

domains, you must use non-meshed ports. (The non-meshed link can be
a port trunk or a single link.) Refer to figure 5-3 on page 5-6.

Multiple Links Between Meshed Switches:

Multiple mesh ports can

be connected between the same two switches, to provide higher band­
width. Each port that you want in the mesh domain should be configured
as

Mesh (and not as a trunk—Trk). Note that if you configure a port as

Mesh, there is no “Type” selection for that port.

Network Monitor Port:

If a network monitor port is configured, broad­

cast packets may be duplicated on this port if more than one port is being
monitored and switch meshing is enabled.

Compatibility with Other Switches:

The switches covered in this guide

operate with the Series 5300xl switches in normal mode.

Rate-Limiting Not Recommended on Meshed Ports: Rate-Limiting
can reduce the efficiency of paths through a mesh domain.

(See also “Operating Rules” on page 5-5.)

For additional information on troubleshooting meshing problems, refer to
“Using a Heterogeneous Switch Mesh” on page 5-7 and “Mesh-Related Prob­
lems” in appendix C, “Troubleshooting” of the Management and Configuration
Guide for your switch.

5-24

Advertising
This manual is related to the following products: