Hearth and Home Technologies 6000TRS-CE User Manual

Page 27

Advertising
background image

27

Roof Pitch

H (min.) cm

flat to 6/12

30.5*

6/12 to 7/12

38*

over 7/12 to 8/12

45.75*

over 8/12 to 9/12

61*

over 9/12 to 10/12

76.25*

over 10/12 to 11/12

99

over 11/12 to 12/12

122

over 12/12 to 14/12

152.5

over 14/12 to 16/12

183

over 16/12 to 18/12

213.5

over 18/12 to 20/12

228.75

over 20/12 to 21/12

244

TERMINATION
CAP

!

WARNING:
FOLLOW NATIONAL REGULATIONS
AND CODES OF PRACTICE FOR
MINIMUM CLEARANCES FROM GAS
TERMINALS, AND PLACEMENT OF GAS
TERMINAL.

NOTE

This also pertains to vertical flue systems installed
on the outside of the building.

VERTICAL

WALL

TERMINATION

CAP

30.5 cm

X

ROOF PITCH

IS X/ 30.5 cm

LOWEST

DISCHARGE

OPENING

H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING

50.8 cm

Figure 24. Minimum Height from Roof to Lowest

Discharge Opening

* 91.4 cm minimum in snow regions