28

V

= VENT TERMINAL

X

= AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

Figure 25 Vent Termination Minimum Clearances

L

= 2.1 M ...................... clearance above paved side-

walk or a paved driveway lo-
cated on public property

M*

= 50.8 cm ................. clearance under veranda, porch,

deck, balcony or overhang

118.9 cm ............... vinyl

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

* only permitted if veranda, porch, deck or balcony is fully open on a

minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 2.1 M
above a sidewalk, driveway, deck, porch, veranda or balcony, use of
a listed cap shield is suggested. (See vents components page)

NOTE 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions specified for
vinyl or non-vinyl siding and soffits. 1. There must be 91.4 cm minimum
between termination caps. 2. All mechanical air intakes within 3.0 M of
a termination cap must be a minimum of 91.4 cm below the termination
cap. 3. All gravity air intakes within 91.4 cm of a termination cap must
be a minimum of 30.5 cm below the termination cap.

M

N

P

R

Q

(See Note 2)

Electrical

Service

V

S

V

S

V

T

D

V

NOTE 3: Local codes or regulations may require different
clearances.

NOTE 4: Termination caps may be hot. Consider their proximity to
doors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere with
access to the electrical service.

NOTE: Vent system termination is permitted in porch areas with
two or more sides open. You must follow all side walls, over-
hang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper perfor-
mance of the appliance when the venting system does not meet
these requirements.

D

E

B

L

v

v

v

v

v

v

v

v

B

B

A

H

M

X

J or K

I

A

G

F

91.4 cm

B

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

Q

MIN

R

MAX

1 cap

91.4 cm

2 x Q

ACTUAL

2 caps

1.8 M

1 x Q

ACTUAL

3 caps

2.7 M

2/3 x Q

ACTUAL

4 caps

3.7 M

1/2 x Q

ACTUAL

Q

MIN

= # termination caps x 3 R

MAX

= (2 / # termination caps) x Q

ACTUAL

N

= 15.3 cm ................. non-vinyl sidewalls

30.5 cm ................. vinyl sidewalls

P

= 2.4 M

Alcove Applications

S = 15.3 cm .................. clearance from sides of

electrical service

T = 30.5 cm ................... clearance above electrical

service

(See Note 5)

(See Note 5)

A

= 30.5 cm ............... clearances above grade, veran-

da, porch, deck or balcony

B

= 30.5 cm ............... clearances to window or door

that may be opened, or to per-
manently closed window.
(Glass)

D

= 50.8 cm ............... vertical clearance to unventilat-

ed soffit or to ventilated soffit lo-
cated above the terminal

= 84.8 cm ............... for vinyl clad soffits and below

electrical service

F

= 22.9 cm .............. clearance to outside corner

G

= 15.3 cm ............... clearance to inside corner

H

= 91.4 cm ............... not to be installed above a gas

meter/regulator assembly within
91.4 cm horizontally from the cen-
ter-line of the regulator

I

= 91.4 cm ............... clearance to gas service regu-

lator vent outlet

J

= 22.9 cm ................. clearance to non-mechanical air

supply inlet to building or the
combustion air inlet to any other
appliance

K

= 91.4 cm ................. clearance to a mechanical (pow-

ered) air supply inlet

(See Note 1)

(See Note 1)