Step 6 the gas supply line – Hearth and Home Technologies 6000TRS-CE User Manual

Page 30

Advertising
background image

30

Figure 28

The gas line should be
installed by a qualified
service technician.

!

Step 6
The Gas
Supply Line

NOTE: Have the gas supply line installed by a
qualified service technician in accordance with
all building regulations
.

NOTE: Before the first firing of the fireplace, the
gas supply line should be purged of any trapped air.

NOTE: Consult local building regulations to
properly size the gas supply line leading to the
(Rp 1/2”) hook-up at the unit.

This gas inlet connection is ISO 7-Rp 1/2 (BSP Rp 1/2).

To install the gas supply line:
• When attaching the pipe, support the control so

that the lines are not bent or torn.

• After the gas line installation is complete, use a

soap solution to carefully check all gas connec-
tions for leaks.

WARNING:
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS
.

• At the gas line access hole, use insulation to

repack the space around the gas pipe.

• Insert insulation from the outside of the fireplace

and pack the insulation tightly to totally seal
between the pipe and the outer casing.

GAS ACCESS

Advertising