Step 5.
Place the wall thimble cover over the pipe assembly and
slide the appliance and vent assembly towards the wall,
carefully inserting the vent pipe into the vent termination
cap assembly. It is important that the vent pipe extend into
the vent termination cap a sufficient distance so as to result
in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the
connection between the vent pipe and the vent termination
cap by attaching the two sheet metal strips extending from
the vent termination cap assembly into the outer wall of
the vent pipe. Use the two sheet metal screws provided to
connect the strips to the pipe section (

Figure 5.9).

Note: The attachment from the vent pipe to the vent
termination cap must be sealed with silicone. Termination
caps shall not be recessed into a wall or siding.

FOLD STRAP

HERE

WALL THIMBLE COVER/CEILING
FIRESTOP AS REQUIRED BY
LOCAL JURISDICTION

1/4 in. (6mm)

STRAP

SHEET METAL SCREW

WALL
THIMBLE

Figure 5.9

WALL THIMBLE
COVER

WALL THIMBLE

VINYL SIDING
STANDOFF WITH
SIDING BENEATH
REMOVED

SCREWS

BOLT HORIZONTAL
TOP TO VINYL
STANDOFF

SCREWS

APPLY SEALANT
TO ALL FOUR
SIDES

VINYL SIDING

Figure 5.8

Burn Risk.
Local codes may require installation of a cap

shield to prevent anything or anyone from
touching the hot cap.

WARNING

WARNING

Do NOT connect a pipe section to a termination cap without
using the telescoping fl ue section found on the termination cap.

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

WARNING

• Ensure vent components are locked together correctly.

• Pipe may separate if not properly joined.

Advertising