Sample sa mp le, And welcome to the quadra-fire family, Caution – Hearth and Home Technologies Hudson Bay Direct Vent Gas Appliance HUDBAY-FS User Manual

Page 2: Attention

Advertising
background image

Page 2

Quadra-Fire • Hudson Bay • 7003-121 Rev. i

10/08

and Welcome to the Quadra-Fire Family

!

Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Quadra-Fire appliance, you
have our assurance of commitment to quality, durability, and
performance.

This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world’s most
advanced technology to achieve the optimum operation of
our stoves, inserts and fi replaces. And yet we are old-fash-
ioned when it comes to craftsmanship. Each appliance is

meticulously fabricated and gold and nickel surfaces are
hand-fi nished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection. From design, to fabrication, to shipping:
Our guarantee of quality is more than a word, it’s Quadra-
Fire tradition, and we proudly back this tradition with a Lim-
ited Lifetime Warranty.

We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: ON BACK OF APPLIANCE

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE

Made in U.S.A. / Fait Aux États-Unis

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details.
This appliance is not convertible for use with other gases, unless a certified kit is used.
/ Cet appareil doit être utilisé
seulement avec le gaz indiqué sur l’étiquette enregistré et peut être installé dans une maison mobile en place permanente
dans les endroits permis par les codes locaux. Voyez le manuel du propriétaire pour des détails supplémentaires. Cet
appareil ne doit pas être converti avec des autres gaz sans l’utilisation d’un ensemble de conversion certifié.

MINIMUM CLEARANCES TO COMBUSTIBLES / ESPACE MINIMUM AUX COMBUSTIBLES
Minimum clearances required from combustible construction for all appliance surfaces. /
Espaces minimum exigés de la construction combustible aux surfaces de l’appareil.

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE Blower Electrical Rating / Évaluation du

Ventilateur Électrique: 115 V., 1.5 Amps, 60 Hz, 150 Watts

ELECTRICAL SUPPLY / FOURNITURE ÉLECTRIQUE: 120 Volts, 1.2 Amps, 60 Hz

Thermal Efficiency up to / Efficacité Thermique Jusqu'à: 84.02% NG (blower on / avec ventilateur allumé)

85.71% LP (blower on / avec ventilateur allumé)

P.4.1-02 Canada Minimum pipe (P.4.1-02 Le canada tuyau minimum) 64.03% NG / 65.43% LP

APPROVED FOR CANADA AND USA TO:
ANSI Z21.88-2002 / CSA 2.33-2002 Vented Gas Fireplace Heaters, and applicable sections of UL307b Gas Burning
Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances
for use at High Altitudes.”
This appliance is manufactured for operation with Natural Gas.
For conversion to propane use Manufacturer’s conversion kit and instructions supplied with the appliance. This
appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is required.

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS:
ANSI Z21.88-2002 / CSA 2.33-2002 Fournaises au Gaz avec Ventilation, et les sections applicable de UL 307b Appareils
de Chauffage Au Gaz pour les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas Fired Appliances for
use at High Altitudes”.
Cet appareil est manufacturé pour l’opération avec le Gaz Naturel.
Pour une conversion au gaz propane les pièces du Manufacturier Cet appareil peut être utilisé dans une chambre à coucher
ou salle de séjour; au Canada, l’installation d’un thermostat à distance est exigée.

CAUTION:

HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP CHILDREN, CLOTHING, FURNITURE,

GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.

ATTENTION:

CHAUD LORQU’IL EST EN OPÉRATION. NE TOUCHEZ PAS. DES BRÛLURES SÉVÈRES PEUVENT EN RÉSULTER.

GARDEZ LES ENFANTS, LES VÊTEMENTS, LES MEUBLES, LA GAZOLINE ET LES AUTRES LIQUIDES DE VAPEUR INFLAMMABLE ÊLOIGNÉS.

CAUTION:

DO NOT OPERATE THIS APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S)

SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.

ATTENTION:

CET APPAREIL NE DOIT PAS ÊTRE OPÉRÉ SI LA VITRE EST BRISÉE, CRAQUÉE OU ENLEVÉE. LE REMPLACEMENT

DU PANNEAU DOIT ÊTRE FAIT PAR UNE PERSONNE LICENSÉE ET QUALIFIÉE.

Date of Manufacture / Date du Manufacturier

2005 2006 2007

Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Jan

7003-122

HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and
strong enough to support the stove without a tipping hazard.
/ CHEMINÉE: Un coussinet non-combustible de cheminée
n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle
sans le hasard de basculer.

This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts
approved)

; if none, follow the National Fuel Gas Code, ANSI Z223.1 or Canadian Installation Codes,

CAN/CGA-B149.

NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or

licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed

plumber or gas fitter.)
Cet appareil doit être installé selon les codes locaux, s'il-y-a-lieu (et approuvé par dans la République de Massachusetts);
sinon suivez les codes THE NATIONAL FUEL GAZ ANSI Z223.1; ou les codes Canadian Installation Codes
CAN/CGA-B149.

REMARQUE: Le conduit gaz doit être installé conformément aux codes de construction locaux. L'installation doit être effectuée

par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la République

de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.)

Keep burner and control compartment clean. See installation and operating instructions accompanying this appliance.
Gardez le brûleur et le compartiment de contrôle propres. Vérifiez les instructions d’installation et d’opération qui accompagnent
cet appareil.

This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m).
In USA for Altitudes above 2000’, the vent configuration, orifice, or combination of both may need to be changed.
See Owner’s Manual for information on making these changes.
/ Cet appareil est équipé pour les altitudes de 0-2000’
(0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ aux
États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le
manuel du propriétaire pour les informations sur ces changements.

This appliance must be properly connected to a venting system in accordance with the manufacturer's installation
instructions.
/ Veuillez lire les instructions d'installation et d'opération qui accompagnent cet apareil

Input Rate on “HI” (BTU/Hr)
Puissance Évaluée à “HI” (BTU/Hr)

Input Rate on “LO” (BTU/Hr)
Puissance Évaluée à "LO" (BTU/Hr)
Main Burner Orifice (DMS)
Orifice du Brûleur Principal

Minimum Inlet Pressure (Inches W.C.)
Pression Minimum de la Valve (pouces W.C.)
Maximum Inlet Pressure (Inches W.C.)
Pression Maximum de la Valve (pouces W.C.)
Manifold Pressure on “HI” (Inches W.C.)
Pression du Collecteur d’ Échappement à “HI” (pouces W.C.)

For use with Natural Gas

Usage au Gaz Naturel

0-2000’

42,000

28,000

.125”

4.5“

7.0”

3.5”

For use with Propane

Usage au Gaz Propane

0-2000’

40,500

31,000

.076”

11“

14”

10”

A.

Top of stove to side wall

B. Side of stove to side wall

C. Back of stove to side wall

D. L/H & R/H corner to side wall

E. Min. alcove floor to ceiling height

F.

Maximum alcove depth

G.

Minimum alcove width

H. Top of stove to ceiling

9" (228.6 mm)
9 5/8” (244.5 mm)
1" (25.4 mm)

4” (101.6 mm)

54” (1372 mm)

36" (914.4 mm)

46.5" (1181 mm)
21” (533.4 mm)

SAMPLE

SA

MP

LE

Report No. / Rapport Numéro

061-S-29b-5

MODEL / MODÈLE

HUDSON BAY

SERIAL NO.

800 West Jefferson Street

Lake City, MN 55041

www.quadrafire.com

002

FOURNAISE AU GAZ AVEC

VENTILATION

NE PAS UTILISER AVEC LE

COMBUSTIBLE SOLIDE

VENTED GAS FIREPLACE HEATER

NOT FOR USE WITH SOLID FUEL

Manufactured Date

Serial Number

Model Name

Test Lab & Report No.

Barcode

Advertising