H. Blower Installation

KIT CONTENTS: Blower; 2 female spade wire connectors.

TOOLS REQUIRED: Powered screwdriver with a #2 Phil-
lips head bit.

Figure 8.20

Disconnect power to the appliance. To access

the blower, open the door located on the front of the pedes-
tal. Remove the two screws holding the blower bracket in
place.

Figure 8.21

Disconnect wires to the blower motor. Remove

the blower from the bracket.

The blower motor comes standard with two male spade
wire connectors. If your appliance has a different con-
nection, use the two female spade wire connectors pro-
vided to modify the appliance wiring harness.

Figure 8.22

Install the new blower by slipping grommets

over studs on the blower bracket. Reinstall the blower and
bracket. Connect the wires. Install screws. Restore power
to the appliance.

Figure 8.23 Blower Wiring Diagram

F

M

F

F

Thermal Disk

Fan Assembly

BLK

BLK

GRN

WHT

BLK

F

M F

M

WHT

Fan Speed Control

BLK

BLK

Strain Relief Bushing

Power Cord (110 VAC)

Ground

WHT

BLK

F = Female spade connector
M = Male spade connector