Hearth and Home Technologies CFX-Crescent User Manual

Page 36

Advertising
background image

Heat & Glo • CFX-CRESCENT • 705-900 Rev. P • 12/07

36

4

Maintaining
and
Servicing
Your
Fireplace

Fireplace
Maintenance

Although the frequency of your fireplace servicing and
maintenance will depend on use and the type of
installation, you should have a qualified service
technician perform an appliance check-up at the
beginning of each heating season. See the table below
for specific guidelines regarding each fireplace
maintenance task.

IMPORTANT

TURN OFF THE GAS BEFORE SERVICING
YOUR FIREPLACE.

Type of

Fireplace

Fireplace Maintenance Task To

Maintenance

Frequency

By

Be Completed

Replacing

Once annually,

Qualified

Brush away loose ember material near

Old Ember

during the

Service

the burner. Replace old ember

Material

annual check-up

Technician

material with new dime-size and -shape
pieces of Golden Ember (GE-93) and
Glowing Ember (050-721). New ember
material should be placed alternately on
top of the burner—a layer of Golden
Ember, a layer of Glowing Ember,
and so on. Save the remaining ember
material and repeat this procedure at
your next servicing. For more
information, see Placing Ember
Material
in the INSTALLERS GUIDE.

Cleaning

Once annually

Qualified

Brush or vacuum the control

Burner

Service

compartment, fireplace logs, and

& Controls

Technician

burner areas surrounding the logs.

Cleaning

Periodically

Qualified

Make a visual check of the straight flame

Flame

Service

sensor rod. Use emery cloth to

Sensor Rod

Technician/

carefully remove any existing white

(IPI System)

Owner

deposits.

Checking

Periodically

Qualified

Make a visual check of your fireplace’s

Flame

Service

flame patterns. Make sure the flames

Patterns,

Technician/

are steady—not lifting or floating. See

Flame Height

Owner

Figure 30.

Checking

Before initial use

Qualified

Inspect the external vent cap on a

Vent System

and at least

Service

regular basis to ensure that no debris is

annually thereafter,

Technician/

interfering with the flow of air. Inspect

more frequently

Owner

entire vent system for proper function.

if possible

Cleaning

After first 3 to 4 hours Homeowner

Remove and clean glass after the first 3

Glass Door

of use. As necessary

to 4 hours of use. After the initial cleaning,

after initial cleaning.

clean as necessary, particularly after
adding new ember (flame colorant)
material. Film deposits on the inside of
the glass door should be cleaned off
using a household glass cleaner.

NOTE: DO NOT handle or attempt to
clean the door when it is hot and
DO NOT use abrasive cleaners.
Refer
to Step 10 for Glass Removal.

Advertising