1.36

MAINTENANCE

Every 200 Hours continued

- Carefully refill the unit with fresh

transmission oil of the recommended grade,

refer to SPECIFICATIONS, until fluid is seen

to flow from the bleed plug aperture. Replace

the cap securely and hand tighten the bleed

plug.

- Remove the plastic reservoir (note this has a left

had thread), from the power unit. Thoroughly

clean and ensure that the mesh screen is fully

open.

- Refit the hydrostatic unit following the

dismantling procedure in reverse order. Torque

the 4 mounting bolts and the fan mounting bolt

to 10.2 - 11.3Nm (7.5 - 8.3 lbs ft).

- Retention the engine drive belt, refer to

RUNNING IN PERIOD.

- Reconnect the connecting pipe.

- Reconnect the ball joint to the actuating lever.

- Replace lower cover and fan guard screen.

- Do not replace the plastic reservoir at this stage.

- Remove the bleed plug from the top of the

hydrostatic unit. Top up through the reservoir

base until oil flows from the bleed plug

aperture and keep topped up during the

following procedure.

WARNING: PREVENT ACCIDENTS - Do not
proceed to the next stage unless all guards have
been replaced and fully secured.

- Start the engine and maintain as low a throttle

setting as possible.

- Ease the machine forwards and backwards

until all residual air has bled from the bleed

plug aperture. Ensure that the reservoir cup is

kept topped up during this process.

- Stop the engine and set the parking brake.

- Replace the bleed plug and secure.

- Replace the reservoir cap and hand tighten.