Section 5 − installation, 1. installing welding generator – Hobart Welding Products CHAMPION 10 User Manual

Page 20

Advertising
background image

OM-945 Page 16

SECTION 5 − INSTALLATION

!

Do not move or operate unit
where it could tip.

!

Do not lift unit from end.

!

Do not weld on base. Welding

on base can cause fuel tank fire

or explosion. Bolt unit down

using holes provided in base.

!

Always securely fasten weld-
ing generator onto transport

vehicle or trailer and comply

with all DOT and other applica-

ble codes.

Do not install unit where air flow is re-

stricted or engine may overheat.

.

See Section 4-2 for lifting eye rat-

ing.

Mounting:

!

Do not mount unit by support-
ing the base only at the four

mounting holes. Do not use

flexible mounts. Use cross-

supports to adequately sup-

port unit and prevent damage

to base.

6

Cross-Supports

Mount unit on flat surface or use

cross-supports to support base.

install2 2008-01 − Ref. 800 652 / Ref. 800 477-A / 803 274-A / 804 712

OR

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Location / Airflow Clearance

5-1. Installing Welding Generator

Mounting

OR

1

Advertising