OM-945 Page 19

5-6. Activating The Dry Charge Battery (If Applicable)

!

Always wear a face shield,
rubber gloves and protective

clothing when working on a

battery.

Remove battery from unit.
1

Vent Caps

2

Sulfuric Acid Electrolyte

(1.265 Specific Gravity)

3

Well

Fill each cell with electrolyte to

bottom of well (maximum).

!

Do not overfill battery cells.

Wait ten minutes and check electro-

lyte level. If necessary, add electro-

lyte to raise to proper level. Reins-

tall vent caps.
4

Battery Charger

!

Read and follow all instruc-
tions supplied with battery

charger.

5

5 Amperes For 30 Minutes

Charge Time

6

30 Amperes For 12 Minutes

Charge Time

Charge battery. Disconnect charg-

ing cables and install battery.

.

When electrolyte is low, add
only distilled water to cells to

maintain proper level.

1

Tools Needed:

2

4

+

3

drybatt1 2008−01 − S-0886

5

6

30 A

5 A

5-7. Connecting the Battery

Ref. 226 427-A / Ref. 802 341 / Ref. S-0756-D