OM-945 Page 22

SECTION 6 − OPERATING THE WELDING GENERATOR

.

If the unit is extremely overloaded, weld and generator power will stop. Turn unit off and restart to reset the generator protection circuit and restore

weld generator power output.

.

If the rated output of the unit is exceeded, engine speed may vary rapidly until the weld or generator load is reduced.

6-1. Front Panel Controls

Ref.226 427-A

4

1

3

2

1

Engine Control Switch

Use switch to start engine, select speed, and

stop engine. In Run/Idle position, engine runs

at idle speed at no load, and weld/power

speed under load. In Run position, engine

runs at weld/power speed.

2

Engine Choke Control

Use control to change engine air-fuel mix.

To Start: pull out choke and turn Engine Con-

trol switch to Start position. Release switch

and slowly push choke in when engine starts.

.

If the engine does not start, let the engine
come to a complete stop before attempt-

ing restart.

.

During cold weather some gasoline en-
gines encounter difficulties that are easily

remedied. See Section 6-2 and 10-1.

To Stop: turn Engine Control switch to Off

position.
3

Engine Hour Meter

4

Amperage Control

Use control to select weld amperage. Select

amperage according to electrode being used

(see Section 6-3). Control may be adjusted

while welding. Control does not affect gener-

ator power output.