OM-945 Page 21

5-10. Connecting To Weld Output Terminals

803 778-A / Ref. 226 427-A

Tools Needed:

4

2

3

Do not place

anything between

Correct Installation

Incorrect Installation

1

weld cable terminal

and copper bar.

3/4 in

!

Stop engine.

!

Failure to properly connect
weld cables may cause ex-

cessive heat and start a fire,

or damage your machine.

1

Weld Output Terminal

2

Supplied Weld Output

Terminal Nut

3

Weld Cable Terminal

4

Copper Bar

Remove supplied nut from weld

output terminal. Slide weld cable

terminal onto weld output terminal

and secure with nut so that weld

cable terminal is tight against cop-

per bar. Do not place anything

between weld cable terminal

and copper bar. Make sure that

the surfaces of the weld cable

terminal and copper bar are

clean.

5-11. Selecting Weld Cable Sizes*

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

Not Exceeding***

100 ft (30 m) or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Weld Output

Terminals

Welding

Amperes

10 − 60%

Duty

Cycle

60 − 100%

Duty

Cycle

10 − 100% Duty Cycle

!

Do not use worn, dam-
aged, undersized, or

poorly spliced cables.

!

Stop engine before
connecting to weld

output terminals.

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

1/0 (60)

1/0 (60)

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

3/0 (95)

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 4/0 (120)

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 2/0

(2x70)

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 3/0

(2x95)

350

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

400

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

2 ea. 4/0

(2x120)

500

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

3 ea. 3/0

(3x95)

3 ea. 3/0

(3x95)

*

This chart is a general guideline and may not suit all applications. If cable overheating occurs, use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

( ) = mm

2

for metric use

S-0007-F