Problem Resolution 5Ć23

Table 5-2. HP FAX-700 and FAX-750 Service Parameters (Continued)

Service

Parameter

Number

Display

Indication

Parameter

Description

Settings

Current

Setting

Standard

Setting

29

SILENT
DETECT IT

Time interval of silence
needed for the 700/750
to detect silence. The de-
fault is 5 seconds, so
there must be a continu-
ous 5 seconds of silence
to the machine to detect
silence

0...99 X 100 ms

50

50

30

MAX RING

Selects the maximum
number of rings before a
communication failure is
recognized

1...20 TIMES

20

20

31

RTC EOL

Selects the end-of-line
indicator to be received
before return to control

01:

EOL *6*

02:

EOL *12

1

1

32

NOT USED

33

MAX XMT
SPEED

Selects the highest trans-
mission speed for the
modem

01: 2400 BPS
02: 4800 BPS
03: 7200 BPS
04: 9600 BPS*

4

4

34

MAX RCV
SPEED

Selects the highest re-
ception speed for the
modem

01: 2400 BPS
02: 4800 BPS
03: 7200 BPS
04: 9600 BPS*

4

4

35

XMT LEVEL

Sets the amplitude of the
output signals trans-
mitted

01: 0 DBM...

16: –15 DBM

9

9

36

RCV LEVEL

Sets the sensitivity of the
fax machine to received
signals

01: –33 DBM...

16: –48 DBM

11

11

37

CABLE
EQUALIZE

Selects whether or not to
Equalize loss (amplitude
distortion) Between Ma-
chine and the phone
company exchange

0:off* / 1:on

0

0

38

ECHO
PROTECT

Selects whether or not to
activate echo protection

0:off / 1:on*

1

1

39

XMT TO RCV
INTRVL

Selects the time interval
between when the fax
machine ceases trans-
mission and is ready to
receive a call

01: 100 ms
02: 200 ms
03: 500 ms*

3

3

40

NSF

Disable/enable non-stan-
dard facility (only
700/750 to 700/750)

0:off / 1:on*

1

1

Advertising