HP 020598 User Manual

Page 5

Advertising
background image

Operating Instructions and Parts Manual

Models 020598 and 020599

5

Operation (continued)

one or two minutes. A suction lift of
20 feet can take 5 minutes running
time to pick up a prime. If pumping
does not start within this time, shut
off the engine, let unit cool down
about 5 minutes, refill pump casing
and retry. If engine does not start,
refer to Engine Manual. If pump
does not prime after 2 tries, refer to
“Troubleshooting Chart” in this man-
ual.

6. Properly fueled and lubricated, the

pump/engine unit will run automati-
cally without attention to the con-
trols. The gasoline engine has a built-
in governor and will adjust the speed
of the engine automatically depend-
ing on the volume of water being
delivered.

Even though this
unit will operate

with minimal supervision, it should not
be left operating by itself. Depending
on the application and area unit is oper-
ating (high traffic, people in area, etc.)
will dictate the necessity of having
someone watching over the unit.

Maintenance

To prevent acciden-
tal starting always

remove spark plug, or disconnect and
ground spark plug wire before attempt-
ing to service or remove any compo-
nent.

1. If the pump is located in an area sub-

ject to freezing temperature, the
pump should be drained when not in
operation. Also, the pump should be

flushed after each use.

2. Clean the suction line strainer at reg-

ular intervals.

3. If the gas engine is equipped with a

spark arrestor screen in the muffler,
it should be inspected for wear peri-
odically, and replaced when neces-
sary.

NOTE: For information pertaining to
the engine and engine parts, consult
the Engine Manual or contact the near-
est authorized service representative or
the manufacturer.

4. Periodically check nuts and bolts on

engine, mounting frame and pump.
Since this is a gas engine pump,
vibration levels tend to loosen nuts
and bolts faster than normal. Use
Loctite (thread sealant) on threads or
lockwashers if necessary.

MECHANICAL SEAL REPLACEMENT

Refer to Figures 1, 2, and 3.

IMPORTANT: Replace seal seat, (Ref.
No. 22) and seal head (Ref. No. 23) at
the same time to ensure proper mating
of mechanical seal components!

1. Unthread fasteners (Ref. No. 16), nuts

(Ref. No. 25) and remove casing (Ref.
No. 15) and casing seal (Ref. No. 7)
from adapter (Ref. No. 3). Unthread
fasteners (Ref. Nos. 11 and 19) and
remove volute (Ref. No. 20) and
volute seal (Ref. No. 6) from adapter.

2. Unthread impeller fastener (Ref. No.

10) and remove impeller (Ref. No. 9),
impeller seal (Ref. No. 4) and shims
(Ref. No. 21).

Performance Chart

GPH of Water at Total Head in Feet

Max.

Model

10'

20'

30'

40'

50'

60'

70'

80'

90'

Head*

020598

8460 7680

6840

6000

5100

4140

3180

2100

840

94 ft.

020599

8460 7920

7440

6960

6360

5760

5040

4200

3360 125

(*) Shut-off; to convert to psi, divide by 2.31

Document2 9/3/03 5:48 PM Page 5