5-2.

Description Of Controls (See Section 5-1)

.

The fan motor is thermostatically
controlled and only runs when cooling is
needed.

Engine Lights

1

Battery Charging Light

Light goes on if engine alternator is not charg-
ing battery. Engine continues to run.

Y

Stop engine and fix trouble if Battery
Charging light goes on.

2

Engine Temperature Light

Light goes on and engine stops if engine tem-
perature is too high.

Y

Stop engine and fix trouble if Engine
Temperature light goes on.

3

Engine Oil Pressure Light

Light goes on and engine stops if oil pressure
is too low. Light goes on momentarily during
start-up but goes out when engine reaches
normal oil pressure.

Y

Stop engine and fix trouble if Engine
Oil Pressure light stays on after start-
up.

4

Glow Plug Light

Light goes on when glow plug is energized and
warming up. Glow plug warms in about six
seconds and engine can be started (see start-
ing instructions following).

Y

Do not use glow plug longer than 20
seconds.

Engine Gauges

5

Engine Hour Meter

6

Fuel Gauge

Weld Controls
7

Dig/Inductance Control

Control adjusts Dig when Stick mode is se-
lected on mode switch. When control is set to-
ward minimum, short-circuit amperage at low
arc voltage is the same as normal welding
amperage.

When set toward maximum, short-circuit am-

perage is increased at low arc voltage to as-
sist with arc starts and help prevent the elec-
trode from sticking while welding (see volt-am-
pere curves in Section 3-4).
Select setting best suited for application.
Control adjusts inductance when MIG or
V-Sense Feeder position is selected on the
mode switch. Inductance determines the
“wetness” of the weld puddle. When set to-
ward maximum, “wetness” (puddle fluidity) in-
creases.
When Pulsed MIG or one of the TIG modes is
selected, this control is not functional.
8

Voltmeter

Meter displays weld voltage and help mes-
sages (see Sections 5-3 and 7-9).
9

Ammeter

Meter displays weld amperage and help mes-
sages (see Sections 5-3 and 7-9).
10 V/A (Voltage/Amperage) Adjustment

Control

11 Mode Switch
The Mode switch setting determines both the
process and output On/Off control (see Sec-
tion 5-4). Source of control (panel or remote)
for the amount of output is selected by the V/A
Control switch.
For Air Carbon Arc (CAC-A) cutting and goug-
ing, place switch in Stick position. For best re-
sults, place Inductance/Dig control in the max-
imum position.
12 V/A (Voltage/Amperage) Control Switch
For front panel control, place switch in Panel
position and use the V/A Adjustment control.
For remote control, make connections to Re-
mote 14 receptacle, and place switch in Re-
mote position. In most modes, remote control
is a percent of V/A Adjustment control setting
(value selected on V/A Adjustment control is
maximum available on remote). In the MIG
mode, remote control provides full range of
unit output regardless of V/A Adjust control
setting.

Engine Starting Controls

13 Glow Plug Switch

Use switch to energize glow plug for cold
weather starting. Glow plug warms in about
six seconds and engine can be started (see
starting instructions following).

14 Engine Control Switch

Use switch to start engine, select speed, and
stop engine. In Run/Idle position, engine runs
at idle speed at no load, and weld/power
speed under load. In Run position, engine
runs at weld/power speed.

.

Place switch in Run position to operate
most GMAW equipment.

To Start:

Above 32

5

F: turn Engine Control switch to

Start. Release switch when engine starts and
Engine Oil Pressure light goes out.

.

If engine does not start, let engine come
to a complete stop before attempting re-
start.

Below 32

5

F: turn engine control switch to

Run/Idle position. Push Glow Plug switch up
and hold about six seconds. Turn Engine Con-
trol switch to Start. Release switch when en-
gine starts and Engine Oil Pressure light goes
out. Do not crank engine while engine is turn-
ing.

.

If engine does not start, let engine come
to a complete stop before attempting re-
start.

To Stop: turn Engine Control switch to Off
position.

.

Push engine stop lever to stop engine if
Engine Control switch does not work (see
item 15).

15 Engine Stop Lever

Use lever to stop engine if Engine Control
switch does not work.

Advertising