OM-492 Page 21

5-5.

Lift-Arc TIG Procedure

With Mode Switch in the Lift-Arc
TIG position, start an arc as follows:

1

TIG Electrode

2

Workpiece

Touch tungsten electrode to work-
piece at weld start point, hold
electrode to workpiece for 1-2
seconds
, and slowly lift electrode.
An arc will form when electrode is
lifted.

Normal open-circuit voltage is not
present before tungsten electrode
touches workpiece; only a low
sensing voltage is present between
electrode and workpiece. The
solid-state output contactor does
not energize until after electrode is
touching workpiece. This allows
electrode to touch workpiece with-
out overheating, sticking, or getting
contaminated.

1

1 – 2

Seconds

“Touch”

Do NOT Strike Like A Match!

2

Ref. S-156 279

Notes